GERMAN CHEMICAL WARFARE MATERIAL |
Part IV - SPECIAL EQUIPMENT |
Section B - COLLECTIVE PROTECTOR EQUIPMENT |
IV–B–9 |
CANISTER, GAS, G-1.2 |
Gasfilter 1,2 |
G 1,2 |
PURPOSE: |
The purpose of this canister is to filter toxic gases from the air drawn into collective protector installations; it is used in conjunction with a smoke filtering canister. |
MARKINGS: |
The side of the canister is marked in white: "G 1,2". |
DESCRIPTION: |
The canister is a short cylinder with slightly convex bottom and top and weighs 34.3 pounds; it is painted dark green. The overall diameter is 16.6 inches and the overall height, 10.6 inches, which includes the two necks, both male threads, 3 inches in dia-meter. Both necks have screw caps to close them when the canister is not in use. |
The canister has two layers of charcoal separated by a fiber gauze; the upper layer is 2.8 inches thick and the bottom, 2.7 inches thick. The capacity of the canister is 1.2 cubic meters of air per minute. |
IV–B–9 |
Canister, Gas, G-1.2 |
Gasfilter 1,2 |
G 1,2 |